Development and Validation of a Stability-indicating RP-HPLC Method for Estimation of Metformin and Rosuvastatin along with Impurities from a Combined Oral Solid Dosage Form

By: Sangeetha, D.
Contributor(s): Vadlamudi, M. K.
Publisher: Mumbai Indian Journal of Pharmaceutical Science 2019Edition: Vol.81(2), Mar-Apr.Description: 355-372p.Subject(s): PHARMACEUTICSOnline resources: Click here In: Indian journal of pharmaceutical sciencesSummary: The objective of current study was to develop and validate a stability-indicating reversed-phase high-performance liquid chromatography for simultaneous quantification of impurities in metformin sustained release-rosuvastatin immediate release combined oral solid dosage form as per International Conference on Harmonisation guidelines. Chromatographic separation was achieved using a Waters high performance liquid chromatography system with a YMC-Pack ODS-A 100×4.6 mm; 3 μm column. Mobile phase A comprised of 20 mM ammonium acetate:acetonitrile (9:1 v/v) pH 3.5, and mobile phase B, consisted of 20 mM ammonium acetate:acetonitrile:methanol (3:5:2 v/v/v) pH 3.5. The gradient program was set as (T/% B) 0/30, 5/30, 10/50, 30/50, 40/80, 42/30 and 45/30, which pumped at a rate of 0.9 ml/min. About 10 μl of sample solutions were injected and monitored at 240 nm. Column temperature and sample compartment was maintained at 25° and 5°, respectively. Forced degradation studies revealed that the peak threshould was more than the peak purity and no purity flag was observed. Repeatability, intra, and inter-day precision results were well within the tolerable limits. Limits of detection were found to be 0.10, 0.05, 0.15, 0.20 and 0.40 ppm and limits of quantitation as 0.30, 0.15, 0.45, 0.60 and 1.0 ppm for metformin, rosuvastatin, rosuvastatin impurity A, B, and C, respectively. The correlation coefficient of linearity for metformin, rosuvastatin and its impurities were found to be ≥0.999. The method recovery was found between 99 and 102 %. The proposed method appeared to be a simple, rapid, economical, accurate, specific, robust and able to distinguish the two key components from their degradants, impurities, and excipients. Therefore, current method could be applied successfully for stability and routine examination
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Pharmacy
Archieval Section
Not for loan 2021036
Total holds: 0

The objective of current study was to develop and validate a stability-indicating reversed-phase high-performance liquid chromatography for simultaneous quantification of impurities in metformin sustained release-rosuvastatin immediate release combined oral solid dosage form as per International Conference on Harmonisation guidelines. Chromatographic separation was achieved using a Waters high performance liquid chromatography system with a YMC-Pack ODS-A 100×4.6 mm; 3 μm column. Mobile phase A comprised of 20 mM ammonium acetate:acetonitrile (9:1 v/v) pH 3.5, and mobile phase B, consisted of 20 mM ammonium acetate:acetonitrile:methanol (3:5:2 v/v/v) pH 3.5. The gradient program was set as (T/% B) 0/30, 5/30, 10/50, 30/50, 40/80, 42/30 and 45/30, which pumped at a rate of 0.9 ml/min. About 10 μl of sample solutions were injected and monitored at 240 nm. Column temperature and sample compartment was maintained at 25° and 5°, respectively. Forced degradation studies revealed that the peak threshould was more than the peak purity and no purity flag was observed. Repeatability, intra, and inter-day precision results were well within the tolerable limits. Limits of detection were found to be 0.10, 0.05, 0.15, 0.20 and 0.40 ppm and limits of quantitation as 0.30, 0.15, 0.45, 0.60 and 1.0 ppm for metformin, rosuvastatin, rosuvastatin impurity A, B, and C, respectively. The correlation coefficient of linearity for metformin, rosuvastatin and its impurities were found to be ≥0.999. The method recovery was found between 99 and 102 %. The proposed method appeared to be a simple, rapid, economical, accurate, specific, robust and able to distinguish the two key components from their degradants, impurities, and excipients. Therefore, current method could be applied successfully for stability and routine examination

There are no comments for this item.

Log in to your account to post a comment.

Click on an image to view it in the image viewer

Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha